Abstract

Using a special determination of the state variables it is noted, that with the faster modes of the conventional reduced order Luenberger observer, a smaller sensitivity to the change of the plant parameters is related. Especially, for the plants with single input and single output (SISO) and no zeros, it is shown that the sufficiently fast observer has a negligible sensitivity to all of the plant parameters. For the SISO plants with some zeros, the number of the plant parameters with respect to which the observer is almost insensitive decreases, if the number of zeros increases. The considerations are extended to the plants with multiple inputs and single output (MISO) and to the MIMO plants. These observations are confirmed by the enclosed results of simulations.

Original languageEnglish
Title of host publication2011 19th Mediterranean Conference on Control and Automation, MED 2011
Pages230-235
Number of pages6
DOIs
Publication statusPublished - 2011
Event2011 19th Mediterranean Conference on Control and Automation, MED 2011 - Corfu, Greece
Duration: 20 Jun 2011 → 23 Jun 2011

Publication series

Name2011 19th Mediterranean Conference on Control and Automation, MED 2011

Conference

Conference2011 19th Mediterranean Conference on Control and Automation, MED 2011
Country/TerritoryGreece
CityCorfu
Period20/06/11 → 23/06/11

ASJC Scopus subject areas

  • Control and Systems Engineering

Fingerprint

Dive into the research topics of 'About robustness of the reduced order Luenberger observer'. Together they form a unique fingerprint.

Cite this